Catalog
Catalog

Technological double-leaf door FD2H series

Used in the food industry and trade. Serves to separate zones with different heat and humidity conditions.
Application:
  • Food industry enterprises
  • Coffee shops, bars, restaurants
  • Food retail enterprises
Advantages
The door with the lock is active. The lock can be installed on both the left and right wing.
The double sealing circuit ensures high sealing of the opening.
The external and internal parts of the aluminum frame allow you to install doors on walls made of sandwich panels without additional load-bearing structures.
The powder-coated aluminum frame can be used in aggressive environments.
The non-threshold design and lower door seal make it possible to level out uneven floors.
The door with the lock is active. The lock can be installed on both the left and right wing.
The double sealing circuit ensures high sealing of the opening.
The external and internal parts of the aluminum frame allow you to install doors on walls made of sandwich panels without additional load-bearing structures.
The powder-coated aluminum frame can be used in aggressive environments.
The non-threshold design and lower door seal make it possible to level out uneven floors.
Design
Sandwich panel surface
Colors
Smooth
Smooth
RAL 9003, white (canvas)
RAL 9003, white (canvas)
RAL 9006, silver (leaf edge)
RAL 9006, silver (leaf edge)
Equipment
Standard
Optional
Aluminum frame.

Aluminum frame.

Door leaf (active and passive leaves).

Door leaf (active and passive leaves).

Set of accessories.

Set of accessories.

Internal aluminum frame.

Internal aluminum frame.

Technical description
Size Table
Opening Dimensions
Construction
Standard Construction
Specifications
Operating Conditions
Packaging
Parameters
Value
Opening width, mm
From 1 000 to 2 400
Opening height, mm
From 1 600 to 2 700
Insulation thickness, mm
40
Headroom, mm
From 60
Sideroom clearance, mm
From 60
  1. Sandwich panels
  2. Aluminum door trim profile
  3. Aluminum frame
  4. Loops
  5. Decorative covers
  6. Bottom seal
  7. Mortise lock

Active sash left.

Active sash left.

Active sash right.

Active sash right.

Parameter Value Notes
Filling thickness, mm 40

To ensure reliable and uninterrupted operation of the doors, it is recommended that they be regularly inspected and serviced.

Manual opening and closing of doors should only be done with the handle.

Do not damage the doors and do not prevent them from opening and closing freely.

Make sure that there are no foreign objects in the opening while opening and closing the doors.

It is forbidden to be in the opening while opening and closing the doors to avoid injury.

It is necessary to promptly clean the moving elements of the structure from contamination.

Packing in wood Packaging features
Length, mm Depends on sash height
Width, mm Depends on sash width
Additional Information print

Technological double-leaf doors have increased anti-corrosion resistance and can be used in aggressive environments.

Installation
Mounting Options
Checking Dimensional Details
Surface mounting.
Surface mounting.
Mounting with inner frame.
Mounting with inner frame.
  1. All measurements are taken indoors. Measurement of each value must be made at least at three different points in order to avoid inaccuracies.
  2. H — the height of the opening (distance from the floor to the top of the opening).
  3. B — opening width (distance from the left edge to the right edge of the opening).
  4. h1 — lintel (distance from the top of the opening to the obstacle).
  5. b1/b2 — left/right lateral distance (distance from the corresponding edge of the opening to the obstacle).
  6. When measuring H and B (height and width of the opening), the largest value is taken as the final size; when measuring h1, b1, b2, the smallest. The discrepancy between the wall levels can be no more than 3 mm, the discrepancy between the diagonals of the opening — no more than 5 mm.
New Products
Mounting without inner frame

Mounting without inner frame

Mounting with inner frame

Mounting with inner frame

The bottom seal provides reliable sealing of the opening

The bottom seal provides reliable sealing of the opening

Design
Sandwich panel surface
Smooth
Smooth
Colors
RAL 9003, white (canvas)
RAL 9003, white (canvas)
RAL 9006, silver (leaf edge)
RAL 9006, silver (leaf edge)
Equipment
Standard
Aluminum frame.

Aluminum frame.

Door leaf (active and passive leaves).

Door leaf (active and passive leaves).

Set of accessories.

Set of accessories.

Optional
Internal aluminum frame.

Internal aluminum frame.

Technical description
Size Table
Parameters
Value
Opening width, mm
From 1 000 to 2 400
Opening height, mm
From 1 600 to 2 700
Insulation thickness, mm
40
Headroom, mm
From 60
Sideroom clearance, mm
From 60
Construction
  1. Sandwich panels
  2. Aluminum door trim profile
  3. Aluminum frame
  4. Loops
  5. Decorative covers
  6. Bottom seal
  7. Mortise lock
Standard Construction

Active sash left.

Active sash left.

Active sash right.

Active sash right.

Specifications
Parameter Value Notes
Filling thickness, mm 40
Operating Conditions

To ensure reliable and uninterrupted operation of the doors, it is recommended that they be regularly inspected and serviced.

Manual opening and closing of doors should only be done with the handle.

Do not damage the doors and do not prevent them from opening and closing freely.

Make sure that there are no foreign objects in the opening while opening and closing the doors.

It is forbidden to be in the opening while opening and closing the doors to avoid injury.

It is necessary to promptly clean the moving elements of the structure from contamination.

Packaging
Packing in wood Packaging features
Length, mm Depends on sash height
Width, mm Depends on sash width
Additional Information

Technological double-leaf doors have increased anti-corrosion resistance and can be used in aggressive environments.

Installation
Mounting Options
Surface mounting.
Surface mounting.
Mounting with inner frame.
Mounting with inner frame.
Checking Dimensional Details
  1. All measurements are taken indoors. Measurement of each value must be made at least at three different points in order to avoid inaccuracies.
  2. H — the height of the opening (distance from the floor to the top of the opening).
  3. B — opening width (distance from the left edge to the right edge of the opening).
  4. h1 — lintel (distance from the top of the opening to the obstacle).
  5. b1/b2 — left/right lateral distance (distance from the corresponding edge of the opening to the obstacle).
  6. When measuring H and B (height and width of the opening), the largest value is taken as the final size; when measuring h1, b1, b2, the smallest. The discrepancy between the wall levels can be no more than 3 mm, the discrepancy between the diagonals of the opening — no more than 5 mm.
Checkout
Managers of the company will answer all
questions by phone: