- Warehouse complexes with low-temperature chambers
- Food industry enterprises, premises with refrigeration and freezing units
Low lift, drum front
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 230 |
B, mm Opening width | B |
A, mm Angle track height | H + 110 |
Ab, mm Height of shaft axle and drum | ≥ A + 59 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 340 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
n, mm Clear opening | 190 (without drive); 0...10 (with drive) |
Low rise, drum at the back.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 150 |
B, mm Opening width | B |
A, mm Angle track height | At h < 170: H + 110; at 150 ≤ h ≤ 170: H + h - 60 |
Ab, mm Height of shaft axle and drum | At h ≤ 170: H + 55; at 150 ≤ h ≤ 170: H + h - 47 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 550 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
n, mm Clear opening | 240 (without drive); 40...60 (with drive) |
Standard lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | R381: ≥ 420; R305: ≥ 350 |
B, mm Opening width | B |
A, mm Angle track height | R381: H+235; R305: H+165 |
Ab, mm Height of shaft axle and drum | A + 97 |
A1, mm Vertical track height | R381: A - 580; R305: A - 490 |
A2, mm Horizontal track height | А - 110 |
E, mm Horizontal track length | R381: H+240; R305: H+290 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
Q, mm Shaft opener position | 300 |
High rise.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > 520 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | Default h - 330 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | A + 86/97 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 510...640 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
Q, mm Shaft opener position | 300 |
High lift, drum bottom.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥1 600 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | 1 330 ≤ HL ≤ h - 150 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | H + 400...600 + 280 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 510...640 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | ≥ 300 |
Q, mm Shaft opener position | ≥ 500 |
Vertical lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ N + 500 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | A + 166 |
A1, mm Vertical track height | H |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
Q, mm Shaft opener position | 300 |
Vertical lift, drum from below.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ H + 120 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | H + 680 |
S, mm Minimum side room clearance | 500 min |
Q, mm Shaft opener position | ≥ 650 |
Parameter | Value | Notes |
---|---|---|
Thermal resistance, m² · °С/W | 2.3 — without a heating system for the opening contour; 3.3 — with heating system for the opening contour | For gates 4 000 x 4 000 mm |
Thermal conductivity, W/m²*°С (DIN4108) | 0.43 — without a heating system for the opening contour; 0.3 — with a heating system for the opening contour | For gates 4 000 x 4 000 mm |
Operating temperature range, °С | ISD TermalPro with a heated circuit — low-temperature chambers down to -30 ° C; ISD TermalPro — medium temperature chambers up to -5 °C | |
Volumetric air permeability, m³/m²*h, class (EN 12426) | 2 class (EN12424:2000) | |
Water resistance limit - minutes, class (EN12425) | 3 class (EN12425:2000) | |
Tightness | 4 class (EN12426:2000) | |
Sound insulation, dB | < 35 | |
Door leaf weight, kg/m² | 16.3 | The exact value depends on the size of the panels used in the gate construction |
Supply voltage, V | 220 V, 50 Hz (for contour heating) | |
Panel thickness, mm | 80 | |
Metal thickness, mm | 0.4 | |
Number of cycles | 120,000 (for gates); 25,000 (for torsion mechanism) | |
Force of manual opening and closing, kg | 22.5 |
1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, that is, its weight must be compensated by the torque of the torsion springs.
2. Make sure that people and animals are not in the area of the gate while it is operating.
3. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.
4. Do not subject the gate to impacts or interfere with its free movement when opening and closing.
5. Do not expose the guides and rollers to contamination, as this can lead to disruption of smooth operation, and if there is an electric drive, to its overload and failure.
6. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.
Packing in cardboard | Packaging features |
---|---|
Description | The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo |
Contents | Cardboard, polystyrene foam, stretch film, tape |
Width, mm | Shield packaging — from 500 to 800 |
Height, mm | Shield packaging — from 350 to 800 |
Length, mm | Shield packaging — from 2 100 to 6 100 |
Gross weight, kg | Up to 1 000 |
Number of items in the packaging | Shield packaging — from 3 to 17 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); additional packaging is possible (edging, delta profile, etc.) |
It is recommended to store sandwich panels in their original packaging on a flat surface. It is recommended to store packages with sandwich panels for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from moisture and, in winter, from snow and dirt. It is necessary to protect them from exposure to direct sunlight, precipitation and dust. Packages must be stored horizontally.
The buyer is provided with a 1 year warranty on the gate.
Low lift, drum front
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 230 |
B, mm Opening width | B |
A, mm Angle track height | H + 110 |
Ab, mm Height of shaft axle and drum | ≥ A + 59 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 340 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
n, mm Clear opening | 190 (without drive); 0...10 (with drive) |
Low rise, drum at the back.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ 150 |
B, mm Opening width | B |
A, mm Angle track height | At h < 170: H + 110; at 150 ≤ h ≤ 170: H + h - 60 |
Ab, mm Height of shaft axle and drum | At h ≤ 170: H + 55; at 150 ≤ h ≤ 170: H + h - 47 |
A1, mm Vertical track height | А - 543 |
A2, mm Horizontal track height | А - 106 |
E, mm Horizontal track length | Н + 550 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
n, mm Clear opening | 240 (without drive); 40...60 (with drive) |
Standard lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | R381: ≥ 420; R305: ≥ 350 |
B, mm Opening width | B |
A, mm Angle track height | R381: H+235; R305: H+165 |
Ab, mm Height of shaft axle and drum | A + 97 |
A1, mm Vertical track height | R381: A - 580; R305: A - 490 |
A2, mm Horizontal track height | А - 110 |
E, mm Horizontal track length | R381: H+240; R305: H+290 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
Q, mm Shaft opener position | 300 |
High rise.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | > 520 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | Default h - 330 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | A + 86/97 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 510...640 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
Q, mm Shaft opener position | 300 |
High lift, drum bottom.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥1 600 |
B, mm Opening width | B |
HL, mm Distance from opening to horizontal tracks level | 1 330 ≤ HL ≤ h - 150 |
A, mm Angle track height | H + HL |
Ab, mm Height of shaft axle and drum | H + 400...600 + 280 |
A1, mm Vertical track height | А - 580 |
A2, mm Horizontal track height | А - 53 |
E, mm Horizontal track length | H - NL + 510...640 |
Db, mm Torsion spring operation space | Depends on the size of the opening and the weight of the shield |
S, mm Minimum side room clearance | ≥ 300 |
Q, mm Shaft opener position | ≥ 500 |
Vertical lift.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ N + 500 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | A + 166 |
A1, mm Vertical track height | H |
S, mm Minimum side room clearance | 120 (150 with the option “heated opening circuit”) |
Q, mm Shaft opener position | 300 |
Vertical lift, drum from below.
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | H |
h, mm Headroom height | ≥ H + 120 |
B, mm Opening width | B |
A, mm Angle track height | 2H + 120 |
Ab, mm Height of shaft axle and drum | H + 680 |
S, mm Minimum side room clearance | 500 min |
Q, mm Shaft opener position | ≥ 650 |
Parameter | Value | Notes |
---|---|---|
Thermal resistance, m² · °С/W | 2.3 — without a heating system for the opening contour; 3.3 — with heating system for the opening contour | For gates 4 000 x 4 000 mm |
Thermal conductivity, W/m²*°С (DIN4108) | 0.43 — without a heating system for the opening contour; 0.3 — with a heating system for the opening contour | For gates 4 000 x 4 000 mm |
Operating temperature range, °С | ISD TermalPro with a heated circuit — low-temperature chambers down to -30 ° C; ISD TermalPro — medium temperature chambers up to -5 °C | |
Volumetric air permeability, m³/m²*h, class (EN 12426) | 2 class (EN12424:2000) | |
Water resistance limit - minutes, class (EN12425) | 3 class (EN12425:2000) | |
Tightness | 4 class (EN12426:2000) | |
Sound insulation, dB | < 35 | |
Door leaf weight, kg/m² | 16.3 | The exact value depends on the size of the panels used in the gate construction |
Supply voltage, V | 220 V, 50 Hz (for contour heating) | |
Panel thickness, mm | 80 | |
Metal thickness, mm | 0.4 | |
Number of cycles | 120,000 (for gates); 25,000 (for torsion mechanism) | |
Force of manual opening and closing, kg | 22.5 |
1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, that is, its weight must be compensated by the torque of the torsion springs.
2. Make sure that people and animals are not in the area of the gate while it is operating.
3. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.
4. Do not subject the gate to impacts or interfere with its free movement when opening and closing.
5. Do not expose the guides and rollers to contamination, as this can lead to disruption of smooth operation, and if there is an electric drive, to its overload and failure.
6. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.
Packing in cardboard | Packaging features |
---|---|
Description | The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo |
Contents | Cardboard, polystyrene foam, stretch film, tape |
Width, mm | Shield packaging — from 500 to 800 |
Height, mm | Shield packaging — from 350 to 800 |
Length, mm | Shield packaging — from 2 100 to 6 100 |
Gross weight, kg | Up to 1 000 |
Number of items in the packaging | Shield packaging — from 3 to 17 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); additional packaging is possible (edging, delta profile, etc.) |
It is recommended to store sandwich panels in their original packaging on a flat surface. It is recommended to store packages with sandwich panels for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from moisture and, in winter, from snow and dirt. It is necessary to protect them from exposure to direct sunlight, precipitation and dust. Packages must be stored horizontally.
The buyer is provided with a 1 year warranty on the gate.