Catalog
Catalog

Industrial sectional doors with panoramic glazing ISD02 China

Panoramic sectional doors of the ISD02 China series consist entirely or partially of panoramic panels, making them ideal for installation in buildings with glazed facades, for example, in car showrooms. They are not inferior in strength to industrial sectional doors of the ISD01 series, since panoramic panels are made of durable aluminum profiles. To increase the energy-saving and thermal insulation properties of doors, DoorHan offers a combination of panoramic and sandwich panels. Panoramic sectional doors of the ISD02 China series have the same safety devices and basic equipment as the industrial sectional doors of the ISD01 series. Sectional doors can be automated using electric drives for industrial and garage doors (the model is selected depending on the area of the door leaf).
Application:
  • Car showrooms
  • Service stations
  • Fire stations
Advantages
Glazing with panoramic panels can withstand blows from a hammer, crowbar, or stone.
The variety of types of gate lifts allows you to install them in rooms with any geometry of the internal space.
The gates are equipped with protection systems against cable breakage and spring breakage, which prevent the door leaf from falling in emergency situations.
A long service life and safety margin, a design that has been proven over the years ensure maximum reliability of the gate throughout its entire service life.
Glazing with panoramic panels can withstand blows from a hammer, crowbar, or stone.
The variety of types of gate lifts allows you to install them in rooms with any geometry of the internal space.
The gates are equipped with protection systems against cable breakage and spring breakage, which prevent the door leaf from falling in emergency situations.
A long service life and safety margin, a design that has been proven over the years ensure maximum reliability of the gate throughout its entire service life.
Design
Panel design
Surface type
Fabric options
Colors
D-Line
D-Line
M-Line
M-Line
V-Line
V-Line
Wood effect (external)
Wood effect (external)
Stucco (internal)
Stucco (internal)
Standard glazing
Standard glazing
Continuous glazing
Continuous glazing
Combined fabric of panoramic and sandwich panels
Combined fabric of panoramic and sandwich panels
RAL 9003 white (basic)
RAL 9003 white (basic)
RAL 9006 silver (basic)
RAL 9006 silver (basic)
RAL 7004 gray (standard)
RAL 7004 gray (standard)
RAL 1014 beige (standard)
RAL 1014 beige (standard)
RAL 6005 green (standard)
RAL 6005 green (standard)
RAL 5005 blue (standard)
RAL 5005 blue (standard)
RAL 7016 anthracite (standard)
RAL 7016 anthracite (standard)
RAL 3000 red (standard)
RAL 3000 red (standard)
RAL 3005 burgundy (standard)
RAL 3005 burgundy (standard)
RAL 8017 brown-red (standard)
RAL 8017 brown-red (standard)
Non-standard color according to RAL card
Non-standard color according to RAL card
Equipment
Standard
Optional
Canvas of panoramic panels. Unbreakable, impact-resistant polycarbonate is used as glazing.

Canvas of panoramic panels. Unbreakable, impact-resistant polycarbonate is used as glazing.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

The torsion mechanism, designed for 25 000 cycles, ensures the durability of the door structure.

The torsion mechanism, designed for 25 000 cycles, ensures the durability of the door structure.

The cable break protection device is installed as a lower bracket on the door leaf. In the event of a cable break, the mechanism is activated and prevents an emergency fall of the door leaf.

The cable break protection device is installed as a lower bracket on the door leaf. In the event of a cable break, the mechanism is activated and prevents an emergency fall of the door leaf.

The spring break protection device blocks the shaft, which prevents the door leaf from accidentally falling.

The spring break protection device blocks the shaft, which prevents the door leaf from accidentally falling.

Box with installation kit, product data sheet and installation instructions.

Box with installation kit, product data sheet and installation instructions.

A mechanical latch allows you to lock the door from inside the room. It is simple and reliable.

A mechanical latch allows you to lock the door from inside the room. It is simple and reliable.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

Torsion mechanism designed for a life of up to 100 000 cycles.

Torsion mechanism designed for a life of up to 100 000 cycles.

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

Technical description
Size Table
Construction
Standard Construction
Specifications
Operating Conditions
Packaging
Parameters
Value
Opening height, mm
2 000–6 000
Opening width, mm
2 000–5 900
Headroom, mm
From 150
Sideroom clearance, mm
From 120
Panoramic panel height, mm
370–720
Panoramic panel width, mm
Not more than 3 000
  1. Vertical guide
  2. Corner post
  3. Cylindrical shaft
  4. Spring break protection device
  5. Drum
  6. U-shaped bracket
  7. Balancing spring mechanism (torsion spring)
  8. Connecting coupling
  9. Internal support bracket
  10. Upper support with roller holder
  11. Side support with roller holder
  12. Inner loop
  13. Cable break protection device
  14. Bottom profile
  15. Panoramic panel
  16. Bottom seal
  17. Side seal
  18. Top profile
  19. Upper seal
  20. Side cover with mounting holes
  21. Translucent impact-resistant panel filling
  22. Spring shock absorber
  23. Ceiling mounting bracket

Low rise, drum at the front.

Low rise, drum at the front.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥ 230; ≥ 260 (with ceiling drive)
B, mm Opening width B
A, mm Angle track height H + 110
Ab, mm Height of shaft axle and drum ≥ A + 59
A1, mm Vertical track height А - 543
A2, mm Horizontal track height А - 106
E, mm Horizontal track length Н + 300
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 185
n, mm Clear opening Up to 190 — without drive; up to 235 — without a drive, with a bottom sandwich panel and an opening width of more than 4 500 mm; up to 10 — with ceiling drive; up to 70 — with a ceiling drive, with a bottom sandwich panel and an opening width of more than 4 500 mm
Low rise, drum at the back.

Low rise, drum at the back.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥ 150; ≥ 180 (with ceiling drive)
B, mm Opening width B
A, mm Angle track height At h < 170: H + 110; at 150 ≤ h ≤170: H + h - 60
Ab, mm Height of shaft axle and drum At h ≤ 170: H + 55; at 150 ≤ h ≤ 170: H + h - 47
A1, mm Vertical track height А - 543
A2, mm Horizontal track height А - 106
E, mm Horizontal track length Н + 510
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 185
n, mm Clear opening 240 (without drive); 40...60 (with ceiling drive)
Standard lift.

Standard lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height R381: ≥ 420; R305: ≥ 350
B, mm Opening width B
A, mm Angle track height R381: H+235; R305: H+165
Ab, mm Height of shaft axle and drum A + 97
A1, mm Vertical track height R381: A - 580; R305: A - 490
A2, mm Horizontal track height А - 110
E, mm Horizontal track length R381: H+200; R305: H+250
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 060
Q, mm Shaft opener position 300
High rise.

High rise.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > 520
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level Default h - 330
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum A + 86/97
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
High lift, drum from below.

High lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥1 600
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level 1 330 ≤ HL ≤ h - 150
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum H + 400...600 + 280
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance ≥ 300
Q, mm Shaft opener position ≥ 500
Vertical lift.

Vertical lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > Н + 500
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum A + 166
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
Vertical lift, drum from below.

Vertical lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > H + 120
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum H + 680
S, mm Minimum side room clearance 500 min
Q, mm Shaft opener position ≥ 650
Parameter Value Notes
Wind load, kg/sqm 2 class (EN12424:2000)
Water resistance limit - minutes, class (EN12425) 3 class (EN12425:2000)
Door leaf weight, kg/m² 17.3
Number of cycles 25 000
Force of manual opening and closing, N 260

1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, that is, its weight must be compensated by the torque of the torsion springs.

2. Manual opening and closing of the gate is carried out only with the help of a handle.

3. When opening and closing the gate manually, do not apply much force to it. Sudden jerks when opening and closing the gate are prohibited.

4. Make sure that people and animals are not in the area of the gate while it is operating.

5. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.

6. Do not subject the gate to impacts or interfere with its free movement when opening and closing.

7. Do not expose the guides and rollers to contamination, as this may impair smooth operation, and in the case of an electric drive, this may lead to its overload and failure.

8. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.

Packing in cardboard Packaging features
Description The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo
Contents Five-layer cardboard, polystyrene foam, stretch film, tape
Width, mm 500–800
Height, mm 200–800
Length, mm 2 100–6 200
Gross weight, kg Up to 1 000
Number of items in the packaging Shield packaging — from 3 to 13 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); Additional packaging is possible (edging, delta profile, etc.)
Additional Information print

It is recommended to store sandwich panels in their original packaging in a horizontal position on a flat surface for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from direct sunlight, precipitation and contamination.

Installation
Mounting Options
Checking Dimensional Details
Surface mounting: the guide system is mounted on the walls and lintel from the inside of the opening.
  1. To take the necessary indicators, a tape measure and a building level are enough. All measurements are taken indoors. Each value must be measured at least at three points (in extreme positions and in the center).
  2. H is the height of the opening (distance from the floor to the top of the opening).
  3. B is the width of the opening (the distance from the left to the right edge of the opening).
  4. h — lintel (distance from the top of the opening to the ceiling) min 150 mm.
  5. b1/ b2 — left/right side distance (distance from the corresponding edge of the opening to the obstacle) min 120 mm.
  6. L is the depth of the room.
  7. When measuring H and B, the largest value is taken as the final size.
  8. When measuring h, b1, b2 and L, the smallest value is taken as the final size.
  9. The difference in floor level across the entire width of the opening should not exceed 10 mm. It is necessary to ensure that the mounting plane (walls and ceiling) is maintained. The base for installing the guide system must be monolithic and durable; if this is not available, additional edging or the formation of an opening with metal products is required.
Warranty print

The buyer is provided with a 1 year warranty.

New Products
Unbreakable, impact-resistant polycarbonate is used as glazing.

Unbreakable, impact-resistant polycarbonate is used as glazing.

Design
Panel design
D-Line
D-Line
M-Line
M-Line
V-Line
V-Line
Surface type
Wood effect (external)
Wood effect (external)
Stucco (internal)
Stucco (internal)
Fabric options
Standard glazing
Standard glazing
Continuous glazing
Continuous glazing
Combined fabric of panoramic and sandwich panels
Combined fabric of panoramic and sandwich panels
Colors
RAL 9003 white (basic)
RAL 9003 white (basic)
RAL 9006 silver (basic)
RAL 9006 silver (basic)
RAL 7004 gray (standard)
RAL 7004 gray (standard)
RAL 1014 beige (standard)
RAL 1014 beige (standard)
RAL 6005 green (standard)
RAL 6005 green (standard)
RAL 5005 blue (standard)
RAL 5005 blue (standard)
RAL 7016 anthracite (standard)
RAL 7016 anthracite (standard)
RAL 3000 red (standard)
RAL 3000 red (standard)
RAL 3005 burgundy (standard)
RAL 3005 burgundy (standard)
RAL 8017 brown-red (standard)
RAL 8017 brown-red (standard)
Non-standard color according to RAL card
Non-standard color according to RAL card
Equipment
Standard
Canvas of panoramic panels. Unbreakable, impact-resistant polycarbonate is used as glazing.

Canvas of panoramic panels. Unbreakable, impact-resistant polycarbonate is used as glazing.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

A set of guides and corner posts made of 2 mm thick steel has an increased margin of safety and has everything necessary for the installation of perforations.

The torsion mechanism, designed for 25 000 cycles, ensures the durability of the door structure.

The torsion mechanism, designed for 25 000 cycles, ensures the durability of the door structure.

The cable break protection device is installed as a lower bracket on the door leaf. In the event of a cable break, the mechanism is activated and prevents an emergency fall of the door leaf.

The cable break protection device is installed as a lower bracket on the door leaf. In the event of a cable break, the mechanism is activated and prevents an emergency fall of the door leaf.

The spring break protection device blocks the shaft, which prevents the door leaf from accidentally falling.

The spring break protection device blocks the shaft, which prevents the door leaf from accidentally falling.

Box with installation kit, product data sheet and installation instructions.

Box with installation kit, product data sheet and installation instructions.

A mechanical latch allows you to lock the door from inside the room. It is simple and reliable.

A mechanical latch allows you to lock the door from inside the room. It is simple and reliable.

Optional
A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

A mechanical lock allows you to block the door leaf in the closed position both from inside the room and from the street.

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

A manual chain drive is installed on industrial doors of all types and is used to raise and lower the door leaf manually.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

It is recommended to install an anti-corrosion package of components if the gate is used in conditions of high humidity to ensure reliable protection against corrosion and stable operation. This package has an increased service life and includes: a painted spring, painted guides, stainless side supports, hinges and hardware, a stainless cable, painted side covers.

Torsion mechanism designed for a life of up to 100 000 cycles.

Torsion mechanism designed for a life of up to 100 000 cycles.

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

Possibility of gate automation with a drive and security systems (see section “Automation for gates”).

Technical description
Size Table
Parameters
Value
Opening height, mm
2 000–6 000
Opening width, mm
2 000–5 900
Headroom, mm
From 150
Sideroom clearance, mm
From 120
Panoramic panel height, mm
370–720
Panoramic panel width, mm
Not more than 3 000
Construction
  1. Vertical guide
  2. Corner post
  3. Cylindrical shaft
  4. Spring break protection device
  5. Drum
  6. U-shaped bracket
  7. Balancing spring mechanism (torsion spring)
  8. Connecting coupling
  9. Internal support bracket
  10. Upper support with roller holder
  11. Side support with roller holder
  12. Inner loop
  13. Cable break protection device
  14. Bottom profile
  15. Panoramic panel
  16. Bottom seal
  17. Side seal
  18. Top profile
  19. Upper seal
  20. Side cover with mounting holes
  21. Translucent impact-resistant panel filling
  22. Spring shock absorber
  23. Ceiling mounting bracket
Standard Construction

Low rise, drum at the front.

Low rise, drum at the front.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥ 230; ≥ 260 (with ceiling drive)
B, mm Opening width B
A, mm Angle track height H + 110
Ab, mm Height of shaft axle and drum ≥ A + 59
A1, mm Vertical track height А - 543
A2, mm Horizontal track height А - 106
E, mm Horizontal track length Н + 300
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 185
n, mm Clear opening Up to 190 — without drive; up to 235 — without a drive, with a bottom sandwich panel and an opening width of more than 4 500 mm; up to 10 — with ceiling drive; up to 70 — with a ceiling drive, with a bottom sandwich panel and an opening width of more than 4 500 mm
Low rise, drum at the back.

Low rise, drum at the back.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥ 150; ≥ 180 (with ceiling drive)
B, mm Opening width B
A, mm Angle track height At h < 170: H + 110; at 150 ≤ h ≤170: H + h - 60
Ab, mm Height of shaft axle and drum At h ≤ 170: H + 55; at 150 ≤ h ≤ 170: H + h - 47
A1, mm Vertical track height А - 543
A2, mm Horizontal track height А - 106
E, mm Horizontal track length Н + 510
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 185
n, mm Clear opening 240 (without drive); 40...60 (with ceiling drive)
Standard lift.

Standard lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height R381: ≥ 420; R305: ≥ 350
B, mm Opening width B
A, mm Angle track height R381: H+235; R305: H+165
Ab, mm Height of shaft axle and drum A + 97
A1, mm Vertical track height R381: A - 580; R305: A - 490
A2, mm Horizontal track height А - 110
E, mm Horizontal track length R381: H+200; R305: H+250
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
P, mm Door opener position Н + 1 060
Q, mm Shaft opener position 300
High rise.

High rise.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > 520
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level Default h - 330
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum A + 86/97
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
High lift, drum from below.

High lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height ≥1 600
B, mm Opening width B
HL, mm Distance from opening to horizontal tracks level 1 330 ≤ HL ≤ h - 150
A, mm Angle track height H + HL
Ab, mm Height of shaft axle and drum H + 400...600 + 280
A1, mm Vertical track height А - 580
A2, mm Horizontal track height А - 53
E, mm Horizontal track length H - NL + 470...600
Db, mm Torsion spring operation space Depends on the size of the opening and the weight of the shield
S, mm Minimum side room clearance ≥ 300
Q, mm Shaft opener position ≥ 500
Vertical lift.

Vertical lift.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > Н + 500
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum A + 166
S, mm Minimum side room clearance 120
Q, mm Shaft opener position 300
Vertical lift, drum from below.

Vertical lift, drum from below.

Symbol, parameter name Calculation formula
H, mm Opening height H
h, mm Headroom height > H + 120
B, mm Opening width B
A, mm Angle track height 2H + 120
Ab, mm Height of shaft axle and drum H + 680
S, mm Minimum side room clearance 500 min
Q, mm Shaft opener position ≥ 650
Specifications
Parameter Value Notes
Wind load, kg/sqm 2 class (EN12424:2000)
Water resistance limit - minutes, class (EN12425) 3 class (EN12425:2000)
Door leaf weight, kg/m² 17.3
Number of cycles 25 000
Force of manual opening and closing, N 260
Operating Conditions

1. Sections of the door leaf must move smoothly along the guides, and the door itself must be balanced, that is, its weight must be compensated by the torque of the torsion springs.

2. Manual opening and closing of the gate is carried out only with the help of a handle.

3. When opening and closing the gate manually, do not apply much force to it. Sudden jerks when opening and closing the gate are prohibited.

4. Make sure that people and animals are not in the area of the gate while it is operating.

5. It is strictly prohibited to move under the moving door leaf, as this can lead to injury.

6. Do not subject the gate to impacts or interfere with its free movement when opening and closing.

7. Do not expose the guides and rollers to contamination, as this may impair smooth operation, and in the case of an electric drive, this may lead to its overload and failure.

8. Make sure that there are no foreign objects or debris in the opening while the blade is moving. Their presence can lead to skewing and jamming of the door leaf.

Packaging
Packing in cardboard Packaging features
Description The guide system and panel of sectional doors have a rigid combined packaging made of cardboard and polystyrene foam, covered with stretch film; the installation kit is packed in a corrugated cardboard box and sealed with packaging film; All packages are equipped with information stickers containing order data, as well as the company logo
Contents Five-layer cardboard, polystyrene foam, stretch film, tape
Width, mm 500–800
Height, mm 200–800
Length, mm 2 100–6 200
Gross weight, kg Up to 1 000
Number of items in the packaging Shield packaging — from 3 to 13 panels; package of guides — 1 guide system; packaging of components — a box with a complete set (there may be several); Additional packaging is possible (edging, delta profile, etc.)
Additional Information

It is recommended to store sandwich panels in their original packaging in a horizontal position on a flat surface for no more than 6 months from the date of production in closed warehouses or under a canopy. The panels must be protected from direct sunlight, precipitation and contamination.

Installation
Mounting Options
Surface mounting: the guide system is mounted on the walls and lintel from the inside of the opening.
Checking Dimensional Details
  1. To take the necessary indicators, a tape measure and a building level are enough. All measurements are taken indoors. Each value must be measured at least at three points (in extreme positions and in the center).
  2. H is the height of the opening (distance from the floor to the top of the opening).
  3. B is the width of the opening (the distance from the left to the right edge of the opening).
  4. h — lintel (distance from the top of the opening to the ceiling) min 150 mm.
  5. b1/ b2 — left/right side distance (distance from the corresponding edge of the opening to the obstacle) min 120 mm.
  6. L is the depth of the room.
  7. When measuring H and B, the largest value is taken as the final size.
  8. When measuring h, b1, b2 and L, the smallest value is taken as the final size.
  9. The difference in floor level across the entire width of the opening should not exceed 10 mm. It is necessary to ensure that the mounting plane (walls and ceiling) is maintained. The base for installing the guide system must be monolithic and durable; if this is not available, additional edging or the formation of an opening with metal products is required.
Warranty

The buyer is provided with a 1 year warranty.

Checkout
Managers of the company will answer all
questions by phone: